1、 Magnetic separator The motor overheats and its sound is abnormal.

Reasons:

1) The bearing is poorly lubricated or severely worn;

2) Fan blade falling off or worn;

3) Poor contact of switch circuit, or single phase running due to disconnection;

4) The voltage is too low.  


 Magnetic separator


2. The sound of the magnetic separator is abnormal during operation, and the cylinder is stuck by obstacles, even making the cylinder unable to rotate, and the bottom box vibrates.  

The reason is often that the cylinder is stuck by the object in the bottom box, and then the magnetic block falls off, making the cylinder rattle, and in serious cases, the cylinder skin will be scratched. At this time, stop for maintenance and troubleshooting.  


3. Reducer overheating

Reasons:

1) Insufficient oil or poor oil quality;

2) The gear and worm are excessively worn, or poorly meshed;

3) The bearing is poorly lubricated or severely worn.

 

4. Magnetic field intensity of magnetic separator is weakened

Reasons:

1) The temperature is too high;

2) Sun exposure;

3) Acid and alkali corrosion. Gauss meter can be used for measurement. The magnetic separator is composed of base, lower magnetic system, rotating cage, upper magnetic system, hollow shaft, concentrate tank, transmission device, etc. The elevation and levelness of the installation base shall be measured with the hollow bearing pad as the benchmark. The positioning of the lower magnetic system is based on the base. The clearance between the rotating cage and the upper and lower magnetic systems must be adjusted accurately, and the clearance deviation is 0+1mm.


Disclaimer: This article is reproduced by editors for the purpose of transmitting more information. If you think our reprint violates the Copyright Law or harms your interests, please contact us in time and we will deal with it in a timely manner.


Recent browsing:

contact us

Contact: President Zhou

Tel: 13607839960

Post code: 541600

Email: [email protected]

Address: Qianjin Road, Guanyang County, Guilin, Guangxi


 Flat magnetic separator

Copyright © Guanyang Zhongnan Magnetic Separation Equipment Co., Ltd. All rights reserved Record No.:
Mainly engaged in Guangxi Guanyang Zhongnan Magnetic Separation Equipment , Magnetic separator , Permanent magnetic roller magnetic separator Welcome to inquire!